• Users Online: 295
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2019  |  Volume : 11  |  Issue : 1  |  Page : 10-15

Functional outcome after management of displaced proximal humerus fractures using angle-stable plates: A prospective study


1 Department of Orthopedics, Dr. Rajendra Prasad Government Medical College, Kangra, Himachal Pradesh, India
2 Department of Pediatrics, Dr. Rajendra Prasad Government Medical College, Kangra, Himachal Pradesh, India

Correspondence Address:
Dr. Vipin Sharma
H. No 21, Type 5, Block B, Dr. Rajendra Prasad Government Medical College, Tanda, Kangra, Himachal Pradesh
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jotr.jotr_3_19

Rights and Permissions

Background: Management of three- and four-part fractures proximal humerus is a surgical challenge. Plate and screw fixation of these fractures is a viable treatment option. The aim of the present study is to analyze the clinical results after proximal humerus fracture fixation using angle-stable implants. Materials and Methods: Forty-eight patients (48 fractures) of the proximal humerus (three and four part, Neer classification) were treated at our institute by proximal angle-stable plates. Patients between 27 and 85 years presented to us during the study (Mean = 51.104 years, range = 27–85 years) over a 1-year and were operated by open reduction and internal fixation with angle-stable plates. Patients were followed up at 3, 6, and 9 months and evaluated using the Constant-Murley and Disabilities of the Arm, Shoulder, and Hand (DASH) scores. Results: The mean follow-up period was 24 months (8–60 months). Fractures united at an average of 12 weeks (range 8–16 weeks) with a mean follow-up of 1.5 years (10–18 months). The mean Constant-Murley and mean DASH scores at final follow-up visit were 67.438 and 17.154, respectively. Conclusion: Despite some complications, the locking plate system is quite efficient in the management of three- and four-part fractures proximal humerus.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed319    
    Printed11    
    Emailed0    
    PDF Downloaded57    
    Comments [Add]    

Recommend this journal